Welcome to UrbanBotaniks Grow Shop
Main menu
-
PromotionsSave
-
Seeds
-
Greenhouses
- Greenhouses
-
Garden solutions
Browse
-
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
-
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
-
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
-
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
-
Soils and pots
- Soils and pots
-
The right foundation
Browse -
Nutrition and care
Browse
-
Fertilizers and additives
-
Hydroponics and irrigation
-
Timers and controllers
-
Measuring instruments
-
Scissors and trimmers
-
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
-
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
-
Gifts
-
Brands
- Brands All brands
-
DUTCHPRO
-
FERRO
-
CELLMAX
-
T.A. - Terra Aquatica
-
Biobizz
-
CANNA
-
ATAMI
-
PLAGRON
-
GREEN HOUSE FEEDING
-
Xpert Nutrients
-
CANNA
Browse BioBizz
Browse
Your cart
Cornwall Temperature Controller, temperature thermostat
246,00 lei
Cornwall temperature controller, ideal for stabilizing the temperature of your crop. It can be used with an air conditioner or other heating appliances (heaters), depending on the selected function.
- Voltage: 230V AC/50HZ
- Maximum load: 16A 3680W
- Inductive load (exhaust fan): 2A 460W
- Operating temperature: 0°C - 40°C
- Storage temperature: -10°C - 50°C
- Controlled temperature: 5°C - 30°C / 40°F - 85°F
- Accuracy: ±1°C / ±3°F
- Reading interval: 10 sec
Please read the instructions before use:
- Before setting the temperature, select the operating mode - cooling (snowflake icon) or heating (flame icon). In "cooling" mode, the unit supplies power when the temperature exceeds the set value; in "heating" mode, it supplies power when the temperature drops below the set value. To change the operating mode - press ON/OFF and "up arrow" together for 3 seconds.
- To switch between °C and °F - press the "up arrow" and "down arrow" together for 3 seconds
- Default setting - cooling; 20°C
- Setting the temperature - press ON/OFF
Cooling mode:
- Use the arrows to set the "SET" temperature at least 2° below the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the snowflake icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is above the "RM" temperature, the indicator will glow red and the controller will not supply power.
Heating mode:
- Use the arrows to set the "SET" temperature at least 2° above the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the flame icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is below the "RM" temperature, the indicator will glow red and the controller will not supply power.
Important:
- Do not connect a power strip after the controller!
- Do not connect devices that transmit vibrations to the controller!
- Ensure the safety of heating and moving appliances!
- Protect from moisture, extreme temperatures, impacts, and vibrations!
- Use indoors only; do not expose to sunlight!
- Keep out of reach of children!
Charge the battery when the device displays "LO" - by plugging the device into the socket!
Distinguish between the maximum load of 16 A / 3680 W and the specified inductive load of 2 A / 460 W. For a motor, compressor, or other inductive appliance, observe the lower permissible limit.
Choosing a climate controller
Match the load type to the control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations for the specific model.
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
Cornwall Temperature Controller, temperature thermostat
246,00 lei
Share:
246,00 lei
246,00 lei
246,00 lei
Description
Cornwall temperature controller, ideal for stabilizing the temperature of your crop. It can be used with an air conditioner or other heating appliances (heaters), depending on the selected function.
- Voltage: 230V AC/50HZ
- Maximum load: 16A 3680W
- Inductive load (exhaust fan): 2A 460W
- Operating temperature: 0°C - 40°C
- Storage temperature: -10°C - 50°C
- Controlled temperature: 5°C - 30°C / 40°F - 85°F
- Accuracy: ±1°C / ±3°F
- Reading interval: 10 sec
Please read the instructions before use:
- Before setting the temperature, select the operating mode - cooling (snowflake icon) or heating (flame icon). In "cooling" mode, the unit supplies power when the temperature exceeds the set value; in "heating" mode, it supplies power when the temperature drops below the set value. To change the operating mode - press ON/OFF and "up arrow" together for 3 seconds.
- To switch between °C and °F - press the "up arrow" and "down arrow" together for 3 seconds
- Default setting - cooling; 20°C
- Setting the temperature - press ON/OFF
Cooling mode:
- Use the arrows to set the "SET" temperature at least 2° below the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the snowflake icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is above the "RM" temperature, the indicator will glow red and the controller will not supply power.
Heating mode:
- Use the arrows to set the "SET" temperature at least 2° above the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the flame icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is below the "RM" temperature, the indicator will glow red and the controller will not supply power.
Important:
- Do not connect a power strip after the controller!
- Do not connect devices that transmit vibrations to the controller!
- Ensure the safety of heating and moving appliances!
- Protect from moisture, extreme temperatures, impacts, and vibrations!
- Use indoors only; do not expose to sunlight!
- Keep out of reach of children!
Charge the battery when the device displays "LO" - by plugging the device into the socket!
Distinguish between the maximum load of 16 A / 3680 W and the specified inductive load of 2 A / 460 W. For a motor, compressor, or other inductive appliance, observe the lower permissible limit.
Choosing a climate controller
Match the load type to the control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations for the specific model.
More solutions for growing
69,00 lei
47,00 lei
2,00 lei
66,00 lei
241,00 lei
69,00 lei
95,00 lei
18,00 lei
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.