Welcome to UrbanBotaniks Grow Shop
Main menu
PromotionsSave
Greenhouses
- Greenhouses
-
Garden solutions
Browse
Seeds
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
Soils and pots
Fertilizers and additives
Hydroponics and irrigation
Timers and controllers
Measuring instruments
Scissors and trimmers
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
Gifts
-
Brands
- Brands All brands
-
CANNA
Browse BioBizz
Browse
Your cart
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
G-systems
Sort by:
- Featured
- Most relevant
- Best selling
- Alphabetically, A-Z
- Alphabetically, Z-A
- Price, low to high
- Price, high to low
- Date, old to new
- Date, new to old
469,00 lei
GSE temperature and minimum-speed controller with 5A socket is a regulator for controlling the speed of one or more extract fans used in indoor growing spaces.
- maintains a constant room temperature
- creates a continuous minimum speed to prevent odour leakage
- max. current: 5.0A
- max. load: 1150W
Setting range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
Technical specifications:
- dimensions W x H x D: 75x110x90mm.
- max. current: 5.0A
- max. load: 1150W
- temperature sensor with a 2m. cable
- voltage: 230V, 50Hz
Setting range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
Installation:
- Plug the fan into socket (5). Connect the temperature sensor (7), which is supplied with a 2m cable, to the controller, then choose the sensor location where you want to take the measurement.
- Ensure it is not directly exposed to a heat source or a flow of light to obtain the most accurate measurement of the surrounding air. Now plug the controller plug (6) into an external outlet. The controller initializes; this can take up to 10 seconds. The green power LED (3) flashes and the fans operate at 50% power. After initialization, the green power LED (3) remains continuously lit — the controller regulates from that point onward.
Instructions:
- Use the temperature-setting knob (1) to set the desired temperature, for example 24°C.
- Use the second knob to set the minimum speed (2), below which the speed must never fall during regulation; for example, set it to 20%.
- The minimum-speed setting has priority and always overrides the temperature setting. If you set the minimum-speed setting (2) to OFF, the fan stops when the measured temperature is below the set temperature. The minimum-speed setting (2) has a 20% start-up boost to give the fan sufficient power to run at low speed.
- Hysteresis is a fixed value of 2°C. Hysteresis is the controlled fan-speed range. Within these 2°C, the fan speed changes from the lowest point set by the minimum-speed setting (2) to the highest regulation point, 100% fan speed, depending on temperature.
- While the temperature measured by sensor (7) is below your setting (24°C), the minimum-speed controller keeps the fan running at the minimum-speed setting (20%). When the temperature rises above 24°C, the temperature LED (4) turns on and the fan speed begins to increase according to temperature over the next 2°C to 100%, until it reaches 26°C.
- Small fans can vary from 0-100%, but if power consumption is higher (large fans), the controller operates semi-variable and automatically switches to 100% without variable control. The controller remains on until the temperature drops.
- Warning! Setting a high minimum speed with large fans will make them run at 100% due to the internal overheating protection! Reduce the minimum speed!
616,00 lei
GSE Temperature and Minimum Speed Controller 10A is a controller for managing the speed of one or more exhaust fans used in indoor growing spaces.
- maintains a constant room temperature
- creates a continuous minimum speed to prevent odour leakage
- max. current: 10.0A
- max. load: 2300W
Setting range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
Technical specifications:
- dimensions W/H/D: 130x92x105mm.
- max. current: 10.0A
- max. load: 2300W
- temperature sensor with 4m. cable
- voltage: 230V, 50Hz
Instructions:
- Use the temperature adjustment knob to set the desired temperature, for example 24°C.
- Use the second knob to set the minimum speed, which must never fall during regulation; for example, we set this to 20%.
- The minimum-speed setting is the strongest setting and always overrides the temperature setting. If you set the minimum-speed setting to OFF, the fan will stop operating when the measured temperature is below the set temperature. The minimum-speed setting has a 20% start-up peak to give the fan enough power to operate at low speed.
- Hysteresis is a fixed value of 2°C. Hysteresis is the controlled range of fan speed. Within these 2°C, the fan speed changes from the lowest point set by the minimum-speed setting to the highest regulation point, 100% fan speed, depending on the temperature.
- While the temperature measured by the sensor is below your setting (24°C), the minimum-speed controller keeps the fan operating according to the minimum-speed setting (20%). When the temperature rises above 24°C, the temperature LED turns on and fan speed begins to increase according to the temperature over the next 2°C up to 100%, until it reaches 26°C.
- Small fans can vary from 0-100%, but if power consumption is higher (large fans), the controller operates semi-variable and automatically switches to 100% without variable control. The controller remains on until the temperature drops.
- Warning! A high minimum-speed setting with large fans will operate at 100% because of the internal overheat protection! Reduce the minimum speed!
Setting range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
This LCD fan controller with built-in display and rotary knob provides very fast, easy setup and reading of all information supplied by the intake and exhaust fan controller. It displays the temperature, humidity and EC extraction fan RPM. An integrated light sensor detects day/night modes. Two 5A / 230V AC outputs are provided for intake and exhaust fans, along with two RJ45 EC outputs; you can choose between a 0-10V or PWM (pulse-width modulation) signal.
Setting ranges:
- Temperature: 15 - 35C°, hysteresis 1 to 5C°
- Humidity: 0 - 100%, hysteresis 1 to 20%
- Min. speed: off, 1 to 100%
- Max. speed: 10 to 100%
- Negative pressure: 0 to 50%
Two internal temperature sensors prevent overheating of the heatsink and processor components. If overheating does occur, variable control switches off and a safety relay protects the exhaust fan while the intake fan is switched off. This prevents a complete ventilation failure and protects your plants.
The controller is ready to use. This reliable fan controller comes with a sealed waterproof cover, covered plugs and a low-voltage sensor, making it ideal for humid rooms. The sensor includes a 4-metre cable. The controller is supplied with a 1.5-metre power cable and a 4-metre sensor cable, which can be extended to 10 metres if required.
Video instructions for use in English and Bulgarian: here* and here*
- Daytime temperature
- Daytime temperature hysteresis
- Daytime humidity
- Daytime humidity hysteresis
- Min. daytime speed
- Max. daytime speed
- Night-time temperature
- Night-time temperature hysteresis
- Night-time humidity
- Night-time humidity hysteresis
- Min. night-time speed
- Max. night-time speed
- Negative pressure setting
- Sensor switching
- Switching between day/night mode
LCD display:
- Graphic and numeric display of constant speed in rpm
- Constant temperature display
- Constant humidity display
- Ability to set the desired conditions
Dimensions and technical specification:
- Enclosure W x H x D: 130 x 92 x 105mm
- Controller W x H x D: 160 x 130 x 105mm
- Designed for: 10A / 2 x 1150W / Triac 2 x 16A
- Voltage: 230V / 50HZ
- Digital sensor 5V measures temperature from –55°C to +125°C (–67°F to +257°F)
- Temperature accuracy from –10 to +85°C: 0.5°C
- Humidity accuracy +/-3%RH, max. tolerance 55%RH
- Protection class: IP54
469,00 lei
G-Systems Timer Box 4x600W + Heating control board with a mechanical timer for managing various lighting types (LED, HPS and MH lamps), used in indoor greenhouses. The timer box allows heating to be switched on when the lighting is not operating.
- max. power: 2400 W
- 3 operating modes (Off / Auto / Off)
- option to switch on heating when the lighting is off
- clock setting: 15-min. segments
Note: The mechanical timer (China) may have a 4-5% time lag, which is why we recommend using the control board with the digital timer G-Systems Timer Box IV 4x600W + Heating!
Note: the timer in the box has no battery; therefore, after a power interruption, it will not switch on automatically.
Technical specification:
- housing: W×H×D= 115 x 228 x 75 mm
- timer box: W×H×D= 150 x 240 x 97 mm
- voltage: 230V / 50Hz
- amperage: 13 A
- power: 2400 W
- operating modes: Off-Auto-On
- clock setting: 15-min. segments
- contactor: electronic
- protection class: IP20
Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Timer/contactor for 6x600W inductive loads.
Dimensions and technical data:
230x300x110mm
230V / 50Hz
24h timer with 36h battery backup, 30min settings.
4x16A 230V
protection rating: IP40
Compatible with 1000W ballasts and lamps:
circuits: 2 x 16A
With magnetic ballast: 4 x 1000W
With electronic ballast: 4 x 1000W
Step transformer that lets you control fans without the low-frequency noise at low speed.
Its six control steps provide better control of the extraction fan according to your selected temperature and humidity settings.
The four buttons allow adjustment of temperature, temperature hysteresis, humidity and humidity hysteresis.
Using the built-in J1 jumper (inside the enclosure), you can choose whether, once the desired temperature and humidity are reached, the fan continues at minimum speed or stops. When J1 is closed, ventilation continues at minimum speed. When it is open, the fan stops completely.
It is supplied with a 4m cable with temperature and humidity sensor, extraction-fan socket and waterproof enclosure.
- temperature range: 20C° - 30C°
- temperature hysteresis: 2C°-8C°
- humidity range: 30% - 100%
- humidity hysteresis: 6%-30%
- size: 265mm x 300mm x 205mm
- max. power: 2,5A
- voltage: 230V / 50HZ
- 5V digital sensor measures temperatures from –55°C to +125°C (–67°F to +257°F)
- accuracy: 0,5C° in the range from -10C° to +85C°; ±4,5%rh
- protection rating: IP54
The controller continuously maintains the set temperature and prevents operation below the specified minimum speed or above the permitted maximum speed.
Hysteresis determines the temperature range. It can be easily controlled by adjusting your desired minimum speed, maximum speed and hysteresis with four knobs. Controller: W x H x D = 160 x 100 x 90 mm Designed for: 10A 2300W Voltage: 230V / 50Hz Digital 5V sensor measures temperatures from -55°C to +125°C (-67°F to +257°F) Accuracy: 0.5°C from -10°C to +85°C Protection rating: IP54Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Timer/contactor for 12 × 600 W inductive loads.
Standard version – single-phase, with 3 power cables.
Dimensions and technical data:
230 × 300 × 110 mm
230 V / 50 Hz
24 h timer with 36 h battery backup, adjustable in 30 min intervals.
4 × 16 A 230 V
protection class: IP40
Compatibility with 1000 W ballasts and lamps:
circuits: 3 × 16 A
With magnetic ballast: 6 × 1000 W
With electronic ballast: 9 × 1000 W
Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Timer/contactor for 12x600W inductive loads.
Variant "+heating" switches on 1 load when the lights are off.
Dimensions and technical specifications:
230x300x110mm
230V / 50Hz
24h timer with a 36h battery, adjustable in 30min increments.
4x16A 230V
protection class: IP40
Compatibility with 1000W ballasts and bulbs:
circuits: 3 x 16A
With magnetic ballast: 6 x 1000W
With electronic ballast: 9 x 1000W
Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Timer/contactor for 6x600W inductive loads.
The "+heating" version includes 1 load when the lights are switched off.
Dimensions and technical data:
230x300x110mm
230V / 50Hz
24h timer with a 36h battery backup, adjustable in 30min increments.
4x16A 230V
protection class: IP40
Compatibility with 1000W ballasts and lamps:
circuits: 2 x 16A
With magnetic ballast: 4 x 1000W
With electronic ballast: 6 x 1000W
A step transformer that lets you control fans without low-frequency noise at low speed.
Its six control steps provide better control of the exhaust fan according to your selected temperature settings.
Two knobs allow you to set the temperature and temperature hysteresis.
Using the built-in J1 jumper (inside the housing), you can choose whether, once the desired temperature is reached, the fan continues at minimum speed or stops. When J1 is closed, ventilation continues at minimum speed. When it is open, the fan stops completely.
It is supplied with a 4m cable with a temperature and humidity sensor, an exhaust-fan outlet and a waterproof enclosure.
- temperature range: 20C° - 30C°
- temperature hysteresis: 2C°-8C°
- dimensions: 265mm x 300mm x 205mm
- max. power: 2,5A
- voltage: 230V / 50HZ
- Digital 5V sensor measures temperatures from –55°C to +125°C (–67°F to +257°F)
- Accuracy: 0,5C° within the range of -10C° to +85C°; ±4,5%rh
- protection rating: IP54
Control panel for operating HPS (sodium) and MH (metal halide) lamps, with a timer that controls lamp switching. On models with a heater output, the heater switches on when the lamps switch off for maximum electricity efficiency. The maximum permissible appliance power is 2000W.
Timer/contactor for 8x600W inductive loads.
Dimensions and technical data:
230x300x110mm
230V / 50Hz
24h timer with 36h battery backup, 30min settings.
4x16A 230V
protection class: IP40
Compatibility with 1000W ballasts and lamps:
circuits: 2 x 16A
With magnetic ballast: 4 x 1000W
With electronic ballast: 6 x 1000W
112,00 lei
- voltage: 230V / 50Hz
- switching time: 15 min
- backup power: no
- manual switching: On - Automatic - Off
Technical specifications:
- Imax: 16 A
- Umax: 230 V
- VAmax: 3600 W
Controller with settings for temperature, minimum speed and negative pressure, controlling inlet and outlet air fans.
Dimensions and technical data:
- Product dimensions: W80xH80xD130mm
- Package dimensions: W150xH110xD170mm
- Designed for: 2A / 2x200W / TRIAC 2x16A
- Voltage: 230V / 50HZ
- The 5V digital sensor measures temperatures from –55°C to +125°C (–67°F to +257°F )
- 0.5°C Accuracy from –10°C to +85°C
- Protection rating: IP54
Setting range:
- Temperature: from 20C° to 30C°
- Minimum speed: off, 20%, 100%
- Negative pressure: 100% to 50%
Instructions for use here!
- The controller manages one or two fans – one for inlet air and one for outlet air, or two for outlet air. Connect the exhaust fan to "Fan 1" and the intake fan to "Fan 2". Set the desired temperature value.
- The "Minimum Speed" setting sets the exhaust fan's minimum speed as a percentage of its maximum speed. At "Off", ventilation stops when not needed; at any other value, it runs at the set speed.
- The "Negative Pressure" setting sets the intake fan speed as a percentage of the exhaust fan speed. If you use this controller for 2 exhaust fans, set it to 100%; otherwise, determine the suitable value experimentally.
- As the temperature rises, fan speed increases gradually, reaching 2° 100% higher. As it decreases, the speed also drops to the value set by "Minimum Speed".
- Maintains a constant temperature, and negative pressure keeps odours contained.
- Can be used for two exhaust fans if the room has unrestricted air access.
- Ready to use and reliable, with a waterproof enclosure, socket covers and a low-voltage sensor, making it ideal for humid rooms.
- The sensor has a 4m cable, which can be extended to 50m.
836,00 lei
🔹 GSE Timer Box IV is a professional lighting and heating controller designed for hydroponic and greenhouse systems. It allows simultaneous control of up to 4 600W lamps and the activation of heating devices with a maximum power of up to 2300W when the lighting is switched off. With a built-in temperature sensor and lamp dimming capability, this controller provides optimal conditions for plant growth.
🔹 Detailed specifications:
- Manufacturer: GSE (G-Systems Engineering)
- Model: Timer Box IV 4x600W + heating + temperature control
- Maximum lighting power: 4x600W
- Maximum heating power: 2300W
- Voltage: 230V / 50Hz
- Switching interval: 30 minutes
- Battery backup: 36 hours
- Relay durability: 10,000,000 cycles
- Protection class: IP54
- Dimensions: 230 x 300 x 110 mm
- Weight: 2 kg
- Certifications: CE, RoHS
- Warranty: 2 years
🔹 Recommendations and instructions for use:
- Connect up to 4 600W lamps to the corresponding controller outputs.
- Connect the heating device to the dedicated heating output.
- Set the desired lighting on and off times using the built-in timer system.
- The controller will automatically switch on the heating when the lighting is switched off to maintain an optimal temperature.
- Regularly inspect and maintain the device to ensure long-lasting and efficient operation.
✅ Benefits of use:
- Efficient energy management: Allows simultaneous control of lighting and heating, optimizing energy consumption.
- Maintaining optimal conditions: Automatically regulates temperature and humidity, creating ideal conditions for plant growth.
- Easy setup and use: An intuitive interface and easy timer setup for lighting and heating.
- High reliability: With long-lasting relay durability and 36-hour battery backup, ensuring uninterrupted operation during power outages.
G-Systems develops climate-control and gardening solutions designed to optimise growing conditions and increase the results from your garden.
CURRENT OFFERS
Promotions
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
When ordering products
over €80
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.