Welcome to UrbanBotaniks Grow Shop
Main menu
PromotionsSave
Greenhouses
- Greenhouses
-
Garden solutions
Browse
Seeds
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
Soils and pots
Fertilizers and additives
Hydroponics and irrigation
Timers and controllers
Measuring instruments
Scissors and trimmers
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
Gifts
-
Brands
- Brands All brands
-
CANNA
Browse BioBizz
Browse
Your cart
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
Calibration Fluids for pH and EC Meters
Sort by:
- Featured
- Most relevant
- Best selling
- Alphabetically, A-Z
- Alphabetically, Z-A
- Price, low to high
- Price, high to low
- Date, old to new
- Date, new to old
11,00 lei
Bluelab KCl is a specialised storage liquid for pH probes and electrodes that protects the sensitive tip from drying out. It ensures proper probe hydration and maintains measurement accuracy. Compatible with:
Product type: storage solution for pH probes and electrodes.
Composition: potassium chloride (KCl) — the same type of solution as the internal electrolyte of pH probes, preventing damage and drying out
Volume: 18 ml (sachet)
Function: keeps the pH probe hydrated, extending its life and ensuring fast response when measuring
Compatibility: suitable for all Bluelab pH meters, probes and pens, as well as other compatible devices.
Advantages:
- prevents the electrode from drying out
- extends the life of the pH probe
- maintains accurate and stable measurements
- convenient single-use format
Recommendations for use:
Probe storage: add a few drops to the pH probe cap and close it to keep the tip continuously moist.
Restoration: if the probe has dried out, soak it in KCl solution for 24 hours before using it again.
Maintenance: use monthly to maintain measurement accuracy and response speed.
Product storage: store in a cool, dry place away from direct light.
16,00 lei
Calibration solution for electrical conductivity (EC) meters – pens, monitors and controllers.
- preset EC value: 2.76 mS/cm
- suitable for Bluelab®
- volume: 300 ml
Electrical conductivity (EC) meters must be calibrated regularly. Follow the instructions supplied with the meter. After use, always rinse the probe with clean water and dry it with a tissue.
The Bluelab Truncheon EC meter does not require calibration! However, it should be checked regularly with this solution. If the reading is low or different from 2.76 mS/cm, the probe tip must be cleaned carefully; also check the batteries.
Storage conditions:
- Store in a cool place!
- Keep out of reach of children!
39,00 lei
Growth Technology pH Probe Cleaner is a specialised cleaning solution developed for safe and effective cleaning of pH probes and electrodes, suitable for BLuelab and Milwaukee. It removes accumulated mineral salts, nutrient residues and organic contaminants that can affect measurement accuracy. Regular use extends the life of pH electrodes and maintains maximum measurement accuracy.
Every pH electrode gradually becomes contaminated during use, especially when measuring nutrient solutions, water with high mineral content or organic solutions. Deposits on the sensitive membrane can lead to a slower response, inaccurate measurements and difficult calibration.Growth Technology pH Probe Cleaner was developed specifically to safely remove these contaminants without damaging the electrode's sensitive structure.
Regular cleaning restores the probe's response speed, improves measurement accuracy and reduces the need for premature electrode replacement. The manufacturer recommends that, after each cleaning, the probe be recalibrated using pH 7.0 and pH 4.0 buffer solutions to ensure the most accurate results.
Growth Technology pH Probe Cleaner is suitable for all Bluelab pH probes and pH meters, including Milawaukee and those from other manufacturers.
Technical specifications
✔️ Manufacturer: Growth Technology
✔️ Type: Cleaning solution for pH probes
✔️ Capacity: 300 ml
✔️ Intended use: Cleaning pH and EC electrodes
✔️ Safe for glass pH electrodes
✔️ Removes mineral deposits and organic contaminants
✔️ Improves measurement accuracy
✔️ Extends the service life of pH probes
✔️ Suitable for regular maintenance of measuring instruments.
Benefits
✔️ Effectively cleans pH and EC electrodes
✔️ Improves probe response speed
✔️ Restores measurement accuracy
✔️ Extends the life of pH electrodes
✔️ Reduces the risk of incorrect readings
✔️ Suitable for all Bluelab and Milwaukee pH instruments
✔️ Easy and safe to use
✔️ Ideal for regular maintenance of measuring equipment.
📋 Instructions for use
- Rinse the pH probe with clean water.
- Apply a small amount of Growth Technology pH Probe Cleaner to a soft brush or directly onto the electrode.
- Carefully clean the glass membrane without applying excessive pressure.
- Rinse thoroughly with clean water.
- Store the probe in pH Probe Refill and Storage.
- Before the next use, calibrate with pH 7.0 and pH 4.0 buffer solutions.
⚠️ Important: Never store a pH electrode in distilled or deionised water. After cleaning, use pH Probe Refill and Storage to prevent the sensitive membrane from drying out and maintain measurement accuracy.
💡 Urban Botaniks tip: Clean the pH probe regularly, especially when working with nutrient solutions high in minerals. Combining pH Probe Cleaner, pH Probe Refill and Storage and regular calibration significantly extends the electrode's life and ensures reliable measurements with every use.
48,00 lei
Water Master pH Probe Refill & Storage Solution KCl 300 ml is a professional solution based on potassium chloride (KCl), designed for the proper storage and maintenance of pH probes and electrodes. It keeps the sensitive membrane constantly hydrated, prevents it from drying out and helps maintain the accuracy and long service life of pH measuring instruments.
Proper storage of the pH probe is an essential part of its maintenance. If the glass electrode dries out, its sensitivity gradually decreases, leading to inaccurate measurements, slower response and a shorter service life. Water Master pH Probe Refill & Storage Solution was developed specifically to prevent this problem by keeping the electrode constantly hydrated and ready for use.
The solution is suitable both for storage and for topping up electrolyte in compatible refillable pH probes. After measurement, the electrode should be rinsed with clean or distilled water, then the protective cap should be filled with a small amount of the KCl solution so that the probe tip remains constantly moist.
Water Master KCl Storage Solution is compatible with most pH testers and pH meters using a glass electrode, regardless of the manufacturer. Regular use reduces measurement drift, facilitates calibration and significantly extends the life of the electrode.
Technical specifications
✔️ Manufacturer: Water Master
✔️ Type: Storage and refill solution for pH probes
✔️ Main ingredient: Potassium chloride (KCl)
✔️ Capacity: 300 ml
✔️ Purpose: Storage and maintenance of pH electrodes
✔️ Suitable for most pH meters with a glass electrode
✔️ Prevents the electrode from drying out
✔️ Improves measurement accuracy and stability
✔️ Suitable for home and professional use.
🔧 Applications
Suitable for:
• pH testers
• pH meters
• pH probes
• Hydroponic systems
• Coco substrates
• Soil growing
• Aquaponics
• Aquariums
• Laboratories
• Water quality monitoring.
📋 Instructions for use
- After completing a measurement, rinse the pH probe with clean or distilled water.
- Pour a small amount of KCl Storage Solution into the electrode's protective cap.
- Fit the cap so that the electrode tip remains in constant contact with the solution.
- If using a refillable probe, top up the solution according to the manufacturer's instructions.
- Replace the used solution regularly – do not return used liquid to the bottle, to avoid contamination.
⚠️ Important: Never store a pH electrode in distilled or deionised water. This can damage the sensitive membrane and reduce measurement accuracy. Always use a dedicated KCl solution for storage.
💡 Tip from Urban Botaniks: Combine this solution with Water Master pH Probe Cleaner: clean the probe first, then store it in the KCl solution. This will ensure maximum measurement accuracy and significantly extend the life of the pH electrode.
Calibration fluids are an important part of maintaining pH and EC measuring instruments. They are buffer solutions with precisely defined values, used to set up and verify measuring-instrument accuracy.
In this category, you will find various solutions for calibrating pH and electrical conductivity, as well as fluids for cleaning and storing electrodes. The most commonly used calibration buffer solutions are pH 4.01, pH 7.00 and pH 10.01, allowing two-point or three-point calibration of pH meters.
Correct calibration is important because electrodes gradually change their characteristics over time and can give inaccurate readings without regular adjustment. Using quality calibration fluids and storage solutions helps maintain measurement accuracy and extend the life of pH probes and EC sensors.
CURRENT OFFERS
Promotions
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
When ordering products
over €80
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.


