{"product_id":"vents-rt-10-room-thermostat-for-automatic-control-of-ventilation-heating-and-air-conditioning","title":"VENTS RT-10 – room thermostat for automatic ventilation, heating and air-conditioning control","description":"\u003cp\u003e\u003cstrong\u003eVENTS RT-10\u003c\/strong\u003e is a compact mechanical room thermostat for automatic control of \u003cstrong\u003efans, heating and air-conditioning systems\u003c\/strong\u003e according to room temperature. It allows the desired temperature to be set in the range \u003cstrong\u003e+10°C to +30°C\u003c\/strong\u003e and, depending on the connection method, can switch equipment on or off when the set temperature threshold is reached. It operates at \u003cstrong\u003e220–240 V \/ 50–60 Hz\u003c\/strong\u003e, has \u003cstrong\u003eIP40\u003c\/strong\u003e protection and is intended for indoor wall mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVENTS RT-10\u003c\/strong\u003e is an easy and reliable solution for automating temperature control in rooms where ventilation, heating or air-conditioning systems operate. Instead of switching the fan or other equipment on and off manually, the RT-10 monitors room temperature and controls the electrical load according to a preset temperature threshold.\u003c\/p\u003e\n\n\u003cp\u003eThe desired temperature is set using the \u003cstrong\u003erotary control on the front panel\u003c\/strong\u003e, with an operating range of \u003cstrong\u003e+10°C to +30°C\u003c\/strong\u003e. The thermostat can operate with different logic depending on the electrical connection – the contacts can open or close as the temperature rises or falls. This allows the RT-10 to be used both for controlling \u003cstrong\u003eventilation\/cooling\u003c\/strong\u003e and in applications where heating control is required.\u003c\/p\u003e\n\n\u003cp\u003eFor example, when used with a fan, the controller can be configured so that the fan \u003cstrong\u003estarts when the set temperature is reached\u003c\/strong\u003e and runs until the temperature falls below the specified threshold. In another configuration, the fan can run until a preset temperature is reached.\u003c\/p\u003e\n\n\u003cp\u003eThe RT-10 has a relatively small \u003cstrong\u003ehysteresis of about 0.5–1°C\u003c\/strong\u003e, allowing the temperature to be maintained within a narrow range around the selected value without excessively frequent switching of the connected equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe housing is made of \u003cstrong\u003eplastic\u003c\/strong\u003e, allowing discreet wall mounting. The manufacturer recommends installing the thermostat at approximately \u003cstrong\u003e1.5 m above the floor\u003c\/strong\u003e, away from windows, doors, heating appliances and other sources that may affect actual temperature measurement.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003e✔️ \u003cstrong\u003eManufacturer:\u003c\/strong\u003e VENTS\u003cbr\u003e\n✔️ \u003cstrong\u003eModel:\u003c\/strong\u003e RT-10\u003cbr\u003e\n✔️ \u003cstrong\u003eType:\u003c\/strong\u003e Room temperature controller \/ thermostat\u003cbr\u003e\n✔️ \u003cstrong\u003eTemperature range:\u003c\/strong\u003e \u003cstrong\u003e+10°C to +30°C\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eHysteresis:\u003c\/strong\u003e \u003cstrong\u003e0.5–1°C\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003ePower supply:\u003c\/strong\u003e \u003cstrong\u003e220–240 V AC\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eMaximum ambient temperature:\u003c\/strong\u003e \u003cstrong\u003e+40°C\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eProtection rating:\u003c\/strong\u003e \u003cstrong\u003eIP40\u003c\/strong\u003e (on the front-panel side)\u003cbr\u003e\n✔️ \u003cstrong\u003eElectrical protection class:\u003c\/strong\u003e \u003cstrong\u003eClass II\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eHousing material:\u003c\/strong\u003e Plastic\u003cbr\u003e\n✔️ \u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cstrong\u003e84 × 84 × 35 mm\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eWeight:\u003c\/strong\u003e up to \u003cstrong\u003e0.13 kg\u003c\/strong\u003e\u003cbr\u003e\n✔️ \u003cstrong\u003eMounting:\u003c\/strong\u003e Vertical indoor wall mounting.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e⚡ Maximum permissible load\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe maximum load depends on the connection configuration used.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor the configuration with higher permissible load:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e✔️ Resistive load: up to \u003cstrong\u003e10 A\u003c\/strong\u003e\u003cbr\u003e\n✔️ Inductive load: up to \u003cstrong\u003e3 A\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor the alternative configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e✔️ Resistive load: up to \u003cstrong\u003e6 A\u003c\/strong\u003e\u003cbr\u003e\n✔️ Inductive load: up to \u003cstrong\u003e2 A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWhen connecting a fan, the permissible \u003cstrong\u003einductive load\u003c\/strong\u003e must be considered, not only the maximum value for resistive load.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e🔄 Control modes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eDepending on the selected electrical wiring diagram, \u003cstrong\u003eVENTS RT-10\u003c\/strong\u003e allows different operating logic:\u003c\/p\u003e\n\n\u003cp\u003e✔️ \u003cstrong\u003eSwitching on when the temperature rises\u003c\/strong\u003e – suitable, for example, for a fan that needs to start when the room becomes too warm.\u003c\/p\u003e\n\n\u003cp\u003e✔️ \u003cstrong\u003eSwitching off when the set temperature is reached\u003c\/strong\u003e – suitable for applications in which the system must operate until the desired temperature threshold is reached.\u003c\/p\u003e\n\n\u003cp\u003e✔️ Using the thermostat as a standard temperature-controlled electrical socket.\u003c\/p\u003e\n\n\u003cp\u003eThis flexibility makes the RT-10 suitable not only for standard domestic ventilation, but also for a variety of professional climate-control applications.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003e📦 The kit includes\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eAccording to the manufacturer's manual:\u003c\/p\u003e\n\n\u003cp\u003e✔️ \u003cstrong\u003e1 × VENTS RT-10 thermostat\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e✔️ Product documentation \/ passport\u003c\/p\u003e\n\n\u003cp\u003e✔️ Installation screws and fasteners\u003c\/p\u003e\n\n\u003cp\u003e✔️ Packaging.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003e🔧 Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eVENTS RT-10 can be used for automatic control of:\u003c\/p\u003e\n\n\u003cp\u003e• Duct fans\u003cbr\u003e\n• Extract ventilation\u003cbr\u003e\n• Supply ventilation\u003cbr\u003e\n• Heating systems\u003cbr\u003e\n• Air-conditioning systems\u003cbr\u003e\n• Greenhouses\u003cbr\u003e\n• Plant nurseries\u003cbr\u003e\n• Storage rooms\u003cbr\u003e\n• Workshops\u003cbr\u003e\n• Technical rooms\u003cbr\u003e\n• Other spaces requiring automatic temperature control.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003e📋 Installation and use\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003col\u003e\n\t\u003cli\u003eChoose a suitable location for installation on the wall.\u003c\/li\u003e\n\t\u003cli\u003eThe recommended height is approximately \u003cstrong\u003e1.5 m above the floor\u003c\/strong\u003e.\u003c\/li\u003e\n\t\u003cli\u003eDo not place the RT-10 directly next to windows, doors, heating appliances or other heat sources.\u003c\/li\u003e\n\t\u003cli\u003eConnect the thermostat according to the appropriate diagram for the desired operating logic.\u003c\/li\u003e\n\t\u003cli\u003eSet the desired temperature using the rotary control.\u003c\/li\u003e\n\t\u003cli\u003eAfter switching on, the system will automatically control the connected equipment according to the room temperature.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e⚠️ \u003cstrong\u003eImportant:\u003c\/strong\u003e The RT-10 operates on \u003cstrong\u003e220–240 V mains voltage\u003c\/strong\u003e. Installation and electrical connection must be carried out with the power supply switched off and by a qualified person, according to the manufacturer's electrical diagram. The thermostat is intended for \u003cstrong\u003eindoor installation\u003c\/strong\u003e and must not be exposed to water, precipitation or direct water splashes.\u003c\/p\u003e\n\n\u003cp\u003e💡 \u003cstrong\u003eAdvice from Urban Botaniks:\u003c\/strong\u003e When controlling ventilation, place the RT-10 where it reflects the actual average temperature of the room. Avoid direct airflow from a fan or air conditioner, as well as immediate proximity to lighting and heating units – otherwise the thermostat may respond to the local temperature rather than the actual conditions in the room.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"Vents","offers":[{"title":"Default Title","offer_id":55114028679510,"sku":"6261","price":159.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/vents-avtomatichen-termo-regulator-rt-10_1d014ab5-1fc2-4283-a910-c9d75a63e47a.webp?v=1787852012","url":"https:\/\/urbanbotaniks.ro\/en\/products\/vents-rt-10-room-thermostat-for-automatic-control-of-ventilation-heating-and-air-conditioning","provider":"UrbanBotaniks Grow Shop","version":"1.0","type":"link"}