{"product_id":"superpro-bac-2","title":"SuperPro BAC-2 Digital Climate Controller","description":"\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:28px;\"\u003e\u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003eDigital temperature and humidity controller with photocell\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eBAC-2 is designed to\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cem\u003e\u003cstrong\u003e control temperature, humidity, carbon dioxide and an additional \"night\" device\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e. The controller has 4 outputs and an external probe with temperature, humidity and photocell sensors. The probe is designed to respond quickly to environmental changes, remain unaffected by electromagnetic emissions (e.g. from ballasts), and is mounted on a 5-metre cable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 220V, 50Hz\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eMaximum current\/power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 10A (~2200W)\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eSensor cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 5m\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eTemperature control range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 5-45°C\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: +\/- 1°C\u003cbr\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cstrong\u003eTemperature control interval (hysteresis)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: As set\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHumidity control range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 5% to 95% RH\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHumidity accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: +\/- 7% RH\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHumidity control interval (hysteresis)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: As set\u003cbr\u003e\n\u003cspan style=\"font-size:18px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cstrong\u003eCO2 ON interval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 1 sec - 12 h\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eCO2 OFF interval\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 1 sec - 96 h\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 2 kg\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: 223x210x92mm\u003cbr\u003e\n\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: IP20\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eINSTALLATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eMount BAC-2 on a wall.\u003c\/p\u003e\n\n\u003cp\u003ePlace the probe in a suitable location where it can receive relevant environmental data - in an area with good air circulation, at an appropriate height, away from direct light.\u003c\/p\u003e\n\n\u003cp\u003eThe probe connects to the controller via a connector. The connector is secured with a quick-release screw.\u003c\/p\u003e\n\n\u003cp\u003eConnect the controller to the mains and the devices to the controller. Ensure the maximum power is not exceeded. If you need to connect more powerful equipment (air conditioner, dehumidifier or heater), use a relay (contactor).\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cstrong\u003eIMPORTANT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e: \u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cem\u003e\u003cstrong\u003eThe probe is not waterproof! Keep it away from water!\u003cbr\u003e\nSet the settings before connecting devices to the controller\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003ePHOTOCELL SENSITIVITY\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003ePress and hold ENTER and UP simultaneously for 3 seconds. The current setting appears on the screen. Adjust it with the arrows. A higher value means greater sensitivity (i.e. weaker light will trigger the photocell). Press ENTER to enter the new setting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eGENERAL INSTRUCTIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eThe controller supplies power to its 4 outputs:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCOOLING OUTPUT (top left) - activates a cooling device (e.g. ventilation or air conditioner).\u003c\/li\u003e\n\t\u003cli\u003eHUMIDITY OUTPUT (bottom right) - activates a dehumidifying or humidifying device.\u003c\/li\u003e\n\t\u003cli\u003eNIGHT OUTPUT (top right) - activates a device that switches on during the dark period.\u003c\/li\u003e\n\t\u003cli\u003eCO2 OUTPUT (bottom left) - activates a device that supplies CO2, or another device that switches on at set intervals. Note: the controller does not measure CO2 levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eBUTTONS AND FUNCTIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eBAC-2 is configured using the buttons on the front panel. Pressing a button displays the corresponding function on the screen. Some buttons have more than one function. The green indicator lights show the selected functions when their respective buttons are pressed.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eUP ARROW - selects a higher value\u003c\/li\u003e\n\t\u003cli\u003eDOWN ARROW - selects a lower value\u003c\/li\u003e\n\t\u003cli\u003eEnter\/Reset - press and hold for 3 seconds to enter new settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eTEMPERATURE BUTTONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eTemp day setting - Sets the temperature during the light period.\u003c\/li\u003e\n\t\u003cli\u003eTemp night setting - Sets the temperature during the dark period.\u003c\/li\u003e\n\t\u003cli\u003eTemp dead-band - Sets the temperature control interval (hysteresis).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHUMIDITY BUTTONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eHumid setting - Sets humidity (for the light or dark period). To set humidity during the light period, press once; the display shows \"day_rH\". To set humidity during the dark period, press twice; the display shows \"nit_rH\".\u003c\/li\u003e\n\t\u003cli\u003eHumid mode - Selects \"humidifying\" (rH Incr) or \"dehumidifying\" (rH decr) mode.\u003c\/li\u003e\n\t\u003cli\u003eHumid dead-band - Sets the humidity control interval (hysteresis).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cstrong\u003eCO2 BUTTONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eCO2 Mode - Selects the operating mode. In \"dAYlocK\" mode, the \"CO2\" output is off if \"Cooling output\" is on (i.e. ventilation is running). In \"dAYFrEE\" mode, the \"CO2\" and \"Cooling output\" outputs can be on at the same time. Use \"dAYFrEE\" if \"Cooling output\" controls an air conditioner.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eCO2 ON time - Sets the interval for which the \"CO2\" output is on.\u003c\/li\u003e\n\t\u003cli\u003eCO2 OFF time - Sets the interval for which the \"CO2\" output is off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eYou can use the \"CO2\" output to control another type of device, such as a circulation pump.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eSPECIAL BUTTONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eTemp \u0026amp; Humid lock - Locks or separates temperature and humidity control. They can be controlled together (COnnEct) or separately (SPLit).\u003c\/li\u003e\n\t\u003cli\u003eSelect \"COnnEct\" when using ventilation to remove excess humidity. In this mode, a rise in temperature or humidity turns on \"Cooling output\".\u003c\/li\u003e\n\t\u003cli\u003eSelect \"SPLit\" if you use ventilation (or an air conditioner) for cooling and a separate device to remove excess humidity. In this mode, a rise in temperature turns on \"Cooling output\", while a rise in humidity turns on \"Humidity output\"\u003c\/li\u003e\n\t\u003cli\u003eSelect \"SPLit\" if you use ventilation (or an air conditioner) for cooling and a separate device to increase humidity.\u003c\/li\u003e\n\t\u003cli\u003eMin \/ Max Temp - Displays the recorded minimum and maximum temperature. Press and hold Enter\/Reset to clear the stored values.\u003c\/li\u003e\n\t\u003cli\u003eMin \/ Max Humid - Displays the recorded minimum and maximum humidity. Press and hold Enter\/Reset to clear the stored values.\u003c\/li\u003e\n\t\u003cli\u003eTo change the unit from °F to °C, press and hold UP and DOWN for 3 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eINDICATOR LIGHTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eBAC-2 can monitor temperature and humidity and warn of issues with the devices it powers.\u003c\/p\u003e\n\n\u003cp\u003eDuring normal controller operation, temperature and humidity change gradually. These changes are detected by the controller. If temperature or humidity does not change at all for 1 hour, the controller switches off the respective device and the corresponding indicator starts flashing. This is a very important function that can prevent serious problems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cstrong\u003eExample\u003c\/strong\u003e\u003c\/span\u003e: The \"Cooling error\" indicator is flashing. This means either the device connected to \"Cooling output\" did not switch on, or the temperature sensor has a problem.\u003c\/p\u003e\n\n\u003cp\u003eTo clear an error, press Enter\/reset.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eFACTORY SETTINGS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003eTemperature during the light period: Temperature during the dark period: Temperature hysteresis:\u003c\/p\u003e\n\n\u003cp\u003eHumidity: 50% Humidity mode: Rh decr (dehumidifying) Humidity hysteresis: 5%\u003c\/p\u003e\n\n\u003cp\u003eCO2 mode: DayFree CO2 ON: 1 min. CO2 OFF: 30 min. Temperature and humidity: separately\u003c\/p\u003e\n\n\u003cp\u003eRestore factory settings: Press and hold Enter \/ Reset for 3 seconds. The display shows \"f.Set\". Press Enter \/ Reset again. The display shows \"doNE\"\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eSETTING PARAMETERS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\n\u003cp\u003ePress a button and the display shows the current setting. Change the value using the arrows. Press Enter to enter the new value.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eQUESTIONS AND ANSWERS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHigh temperature is detected\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: Do not position the probe directly beneath the lamps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eThe display shows \"Err SEn\"\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: Sensor error. Switch off the controller, disconnect the sensor, reconnect it and restart.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eHumidity rises instead of falling (or vice versa)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: Select the correct mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eThe CO2 timer does not keep accurate time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: Replace the battery (CR1220, 3V, 5-year life).\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"font-size:18px;\"\u003e\u003cstrong\u003eThe controller does not supply power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e: Restart it using the button at the bottom of the housing. Check the power rating of the devices connected to the controller. If necessary, use a relay (contactor).\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp style=\"text-align: center;\"\u003e\u003cspan style=\"font-size:28px;\"\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cstrong\u003eIMPORTANT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cem\u003e\u003cstrong\u003eKeep these instructions and follow them in full. Observe all warnings.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cem\u003e\u003cstrong\u003eDo not use near water! Do not install near heat sources. Do not block the ventilation openings!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cem\u003e\u003cstrong\u003eDo not attempt to repair the controller! Do not use it if the power cable insulation is damaged!\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:arial,helvetica,sans-serif;\"\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cem\u003e\u003cstrong\u003eThe controller has a built-in circuit breaker against short circuits or overloads. All outputs are grounded; connect only to an earthed socket.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e","brand":"No Brand","offers":[{"title":"Default Title","offer_id":55115789140310,"sku":"12318","price":1003.0,"currency_code":"RON","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/product_1967.jpg?v=1787849813","url":"https:\/\/urbanbotaniks.ro\/en\/products\/superpro-bac-2","provider":"UrbanBotaniks Grow Shop","version":"1.0","type":"link"}