{"product_id":"milwaukee-ma911b-2-ph-probe-for-mc110-pro","title":"MA911B\/2 replacement pH probe for Milwaukee MC110 PRO","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003eMilwaukee MA911B\/2\u003c\/strong\u003e\u003c\/span\u003e is a \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003ereplacement pH probe\u003c\/strong\u003e\u003c\/span\u003e for the pH meter \u003cu\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.urbanbotaniks.com\/product\/916\/milwaukee-mc110-pro-ph-monitor-mid-range-ured-za-izmervane-na-ph.html\"\u003eMilwaukee MC110 PRO\u003c\/a\u003e\u003c\/strong\u003e\u003c\/u\u003e (\u003cspan style=\"color:#FF0000;\"\u003e\u003cstrong\u003esold separately\u003c\/strong\u003e\u003c\/span\u003e).\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003emeasures: \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003etemperature\u003c\/strong\u003e\u003c\/span\u003e of solutions\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003emeasurement range: \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e0.0 - 14.0 pH\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003eoperating environment: \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/span\u003e to \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e70°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003edimensions: \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e12 \/ 16 cm\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color:#000000;\"\u003e,\u003c\/span\u003e\u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e \u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e⌀ 1.27 cm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003e\n\u003cspan style=\"color:#000000;\"\u003ecable length:\u003c\/span\u003e\u003cspan style=\"color:#008000;\"\u003e\u003cstrong\u003e 2 m\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003econnection: \u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003eBNC\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003ewarranty: \u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003e6 months\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003eYou can extend the life of your pH electrode as follows:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003col\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003e\n\u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003eStorage:\u003c\/strong\u003e\u003c\/span\u003e The pH probe must be kept hydrated. Long periods of dry storage will harm the probe's sensitivity. Allowing the probe to dry may also cause deposits and clogging at its tip. Storing it in \u003cu\u003e\u003ca href=\"https:\/\/www.urbanbotaniks.com\/product\/1160\/milwaukee-ma9015-storage-solution-for-ph-orp-electrodes-230ml-raztvor-za-sahranenie-na-ph-senzori.html\"\u003e\u003cstrong\u003eMA9015 storage solution\u003c\/strong\u003e\u003c\/a\u003e\u003c\/u\u003e or pH calibration buffers will help address both issues. \u003cspan style=\"color: rgb(255, 0, 0);\"\u003e\u003cstrong\u003eDo not store in tap water or distilled water!\u003c\/strong\u003e\u003c\/span\u003e This will damage the probe's sensitivity. The best way to store the probe is with the probe cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that the electrode be stored upright to further reduce the potential for leakage.\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003e\n\u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003eCleaning:\u003c\/strong\u003e\u003c\/span\u003e Deposits on the probe tip from the mineral salts of the nutrient solution or from organic material can affect its sensitivity and clog it. We recommend regularly soaking your electrode in \u003cu\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.urbanbotaniks.com\/product\/1159\/milwaukee-ma9016-cleaning-solution-for-ph-orp-electrodes-230ml-raztvor-za-pochistvane-na-ph-senzori.html\"\u003eMA9016 cleaning solution\u003c\/a\u003e\u003c\/strong\u003e\u003c\/u\u003e.\u003c\/li\u003e\r\n\t\u003cli style=\"text-align: justify;\"\u003e\n\u003cspan style=\"color: rgb(0, 128, 0);\"\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003c\/span\u003e the glass tip of the pH probe becomes less sensitive over time, so make sure to calibrate regularly to keep your meter accurate. Also calibrate after cleaning or a long period of storage.\u003c\/li\u003e\r\n\u003c\/ol\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":55115728585046,"sku":"11328","price":366.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/rezervna-ph-sonda-ma911b-2-za-milwaukee-mc110-pro.webp?v=1787849759","url":"https:\/\/urbanbotaniks.ro\/en\/products\/milwaukee-ma911b-2-ph-probe-for-mc110-pro","provider":"UrbanBotaniks Grow Shop","version":"1.0","type":"link"}